Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Int Ophthalmol ; 43(1): 325-331, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35918497

RESUMO

PURPOSE: To evaluate corneal biomechanical changes using Corvis ST in patients treated with photorefractive keratectomy (PRK) 25 years ago. METHODS: In this study, 32 post-PRK and 38 normal eyes underwent Corvis ST (CST) assessments. The measured CST factors were: time of highest concavity (HC), time of applanation 1 (AT1), time of applanation 2 (AT2), length of applanation 1 (AL1), length of applanation 2 (AL2), velocity of applanation 1 (AV1), velocity of applanation 2 (AV2), deformation amplitude (DA), peak distance (PD), integrated radius (IR), Ambrosio relational thickness horizontal (ARTh), stiffness parameter at first applanation (SP-A1), DA ratio (2 mm), Belin/Ambrosio enhanced ectasia display (BAD) and corneal biomechanical index (CBI). RESULTS: The mean [± standard deviation (SD)] age was 51.4 ± 7.36 years in PRK, 51.4 ± 3.62 in control group. PRK was performed 24.69 ± 1.78 years ago. ARTh, SP-A1, AT1, AL1, and AL2 were lower in PRK. PD, AT2, DA ratio (2 mm), and IR were statistically higher in PRK (P < 0.01). In PRK and control group the mean value of CBI was 0.91 ± 0.11 and 0.50 ± 0.27 (P < 0.001), and mean value of BAD was 3.34 ± 1.53 and 1.1 ± 0.70 (P < 0.001). In PRK 71.9% of eyes were classed "high risk CBI plus diseased BAD" and 25% remained in the "high risk CBI and normal BAD" group. CONCLUSIONS: In this study, most of the post-PRK eyes which were clinically and topographically normal were classified as "high risk CBI plus diseased BAD" and had significantly worse CBI and BAD values than the control group. This leads to the conclusion that CBI and BAD alone are not appropriate to evaluate post-PRK ectasia.


Assuntos
Miopia , Ceratectomia Fotorrefrativa , Humanos , Adulto , Pessoa de Meia-Idade , Dilatação Patológica , Tonometria Ocular , Pressão Intraocular , Córnea/cirurgia , Miopia/cirurgia , Fenômenos Biomecânicos
2.
Eur J Ophthalmol ; 33(1): 44-51, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36062606

RESUMO

PURPOSE: To evaluate the efficacy and safety of silicone hydrogel contact lens-assisted corneal cross-linking (CL-CXL) and compare 12-month visual and topographic outcomes with accelerated CXL using hypo-osmolar riboflavin (A-CXL) in keratoconus patients with thin corneas (below 400 µm with epithelium). METHODS: This retrospective study included 27 eyes of 27 keratoconus patients who underwent CL-CXL (n = 14) or A-CXL (n = 13). Uncorrected and corrected distance visual acuity (UDVA and CDVA) and data obtained from corneal topography were analyzed at baseline and again at 6- and 12-month follow-ups. Corneal demarcation line depth (DLD) was measured at one month, and changes in the corneal endothelial cell density (ECD) at 12 months were also assessed. RESULTS: Mean UDVA improved significantly in both groups at 12 months (all p < 0.05). Maximum keratometry (K-max) decreased by 1.04 ± 1.90 D in the CL-CXL group and by 0.87 ± 1.89 D in the A-CXL group at 12 months, which was not statistically significant (all p>0.05). Total corneal higher-order aberrations (HOAs) analysis showed a significant improvement in only the CL-CXL group at 12 months (p = 0.041). Average DLD was 227.18 ± 65.60 µm in the CL-CXL group and 245.30 ± 66.84 µm in the A-CXL group (p = 0.275). No significant change in ECD was found in either group (all p>0.05). Mean changes in UDVA, CDVA, K-max, K-mean, HOAs, and ECD were not statistically significant between the groups (all p>0.05). CONCLUSIONS: Silicone hydrogel CL-assisted CXL seems as effective as A-CXL in halting keratoconus progression in thin corneas with no side effects during the one-year follow-up period.


Assuntos
Lentes de Contato , Ceratocone , Fotoquimioterapia , Humanos , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Hidrogéis/uso terapêutico , Raios Ultravioleta , Seguimentos , Colágeno/uso terapêutico , Reagentes de Ligações Cruzadas/uso terapêutico , Córnea , Riboflavina/uso terapêutico , Topografia da Córnea
3.
J Refract Surg ; 38(10): 674-681, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36214347

RESUMO

PURPOSE: To evaluate the biomechanical changes and advanced oxidation protein products (AOPP) production after different corneal cross-linking (CXL) protocols with or without oxygen supplementation. METHODS: Ovine eyes in the study were equally distributed to five groups as control, standard Dresden protocol, diluted alcohol- and iontophoresis-assisted CXL (DAI-CXL), and 0.1% and 0.2% riboflavin-mediated iontophoresis-assisted CXL with oxygen supplementation (I-CXL). Corneas that received CXL were divided into two equal parts, one part was used for uniaxial tensiometry and one part was used for AOPP measurement. RESULTS: All treatment groups showed higher Young's modulus and stiffness compared to the control group (P < .05). Both oxygen-assisted I-CXL groups with 0.1% and 0.2% riboflavin concentrations had higher corneal Young's modulus (P = .009 and .006, respectively) and stiffness (P = .009) values, whereas the DAI-CXL group had lesser Young's modulus and stiffness values (P = .032) compared to the Dresden protocol group. All treatment groups showed higher AOPP concentrations compared to the control group (P < .05). DAI-CXL and I-CXL groups showed similar AOPP formation compared to the Dresden protocol (P = .673). CONCLUSIONS: When the epithelium is intact, the desired increase in corneal stiffness might not be achieved. However, increasing the oxygen in the environment might provide a sufficient increase in stiffness in cases undergoing epitheliumon I-CXL, which might be promising in terms of shortening the CXL therapy and decreasing the complications. [J Refract Surg. 2022;38(10):674-681.].


Assuntos
Produtos da Oxidação Avançada de Proteínas , Iontoforese , Produtos da Oxidação Avançada de Proteínas/metabolismo , Animais , Colágeno/metabolismo , Córnea/metabolismo , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas , Humanos , Oxigênio/metabolismo , Oxigenoterapia , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina , Ovinos , Raios Ultravioleta
4.
Curr Eye Res ; 47(10): 1413-1418, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35748851

RESUMO

PURPOSE: The aim of this study was to evaluate the use of monopolar radiosurgery (MRS) assisted strabismus surgery and to compare its histologic and immunohistochemical wound healing outcomes with conventional surgery. METHODS: Superior rectus muscle resection was performed on 30 white rabbits with three different surgical muscle cutting techniques: monopolar radiosurgery (MRS group), conventional scissors preceded by bipolar electrocautery (BEC group), and conventional scissors with no cauterization (control group). Degree of tissue injury, bleeding, inflammation, and fibrosis, as well as wound healing rate (CD68+ cell number), were evaluated. RESULTS: In CS group, hemorrhage scores were significantly higher than those in the other groups (MRS group: Z = 5.182; p < 0.001 and BEC group: Z = 4.463; p < 0.001) and MRS group had lower scores than BEC group; however, the difference was not significant (Z = 1.423; p = 0.211). The tissue injury score in BEC group was higher when compared with MRS, and the difference was statistically significant (p = 0.028). Median inflammation scores at days 1 and 21 were lowest in MRS group, but the difference was not statistically significant among groups (day 1; p = 0.115, day 21; p = 0.095). The median fibrosis score was higher in the control group, when compared with MRS, and the difference was statistically significant (muscle-sclera; p = 0.011 and muscle-conjunctiva: p = 0.003). The macrophage score (number of CD68+ cells) was lowest in CS group; however, the difference was not significant (p = 0.657). CONCLUSIONS: Monopolar radiosurgery is a novel method for strabismus surgery and provides equivalent hemostasis effects and wound healing properties, compared with conventional methods, and enhances surgeon comfort, as muscle incisions are made in one step with clean surgical area.


Assuntos
Radiocirurgia , Estrabismo , Animais , Fibrose , Inflamação , Músculos Oculomotores/cirurgia , Complicações Pós-Operatórias/cirurgia , Coelhos , Estrabismo/cirurgia
5.
Cornea ; 41(4): 462-469, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34743098

RESUMO

PURPOSE: The aim of this study was to compare the 4-year clinical outcomes of transepithelial diluted alcohol and iontophoresis-assisted corneal crosslinking (DAI-CXL) and standard corneal crosslinking (S-CXL) in adults with progressive keratoconus. METHODS: This retrospective study included 36 eyes of 36 keratoconic patients who underwent DAI-CXL (n = 18) or S-CXL (n = 18). Best spectacle-corrected visual acuity (BSCVA) and corneal topography parameters were analyzed at baseline and at 1, 2, 3, and 4 years of follow-up. Corneal demarcation line depth (DLD) at 1 month was measured, and the relation of DLD with corneal thickness (DL%) was assessed. RESULTS: BSCVA improved significantly only in S-CXL (P = 0.01). A significant decrease in maximum keratometry and mean keratometry occurred at 4 years in both groups (all P < 0.05), and these changes were similar in both groups (all P > 0.05). There was a significant reduction in the thinnest corneal thickness in S-CXL (P = 0.01); however, the mean thinnest corneal thickness in DAI-CXL remained stable (P = 0.094). Higher-order aberrations and coma aberration decreased significantly in both groups at 4 years (all P < 0.05), with a higher decrease in S-CXL (all P < 0.05). Spherical aberration showed a significant reduction only in S-CXL (P = 0.005). In contrast to the similar mean DLD in both groups, DL% in DAI-CXL was significantly greater than that in S-CXL (P = 0.032). There were no correlations between the improvement in BSCVA, maximum keratometry, mean keratometry, higher-order aberrations, and the mean DLD and DL% (all P > 0.05). CONCLUSIONS: DAI-CXL was as effective as S-CXL in arresting the progression of keratoconus and showed similar clinical results to S-CXL at the 4-year follow-up.


Assuntos
Reagentes de Ligações Cruzadas/uso terapêutico , Epitélio Corneano/efeitos dos fármacos , Etanol/administração & dosagem , Iontoforese/métodos , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Adulto , Colágeno/metabolismo , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Fotoquimioterapia/métodos , Estudos Retrospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
6.
Eye (Lond) ; 35(11): 3147-3151, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34363049

RESUMO

BACKGROUND: To evaluate the singlet oxygen (1O2) production of oxygen assisted %0.1 riboflavin and ultraviolet-A (UVA) crosslinking therapy (with and without oxygen assistance), in combination with standard, accelerated and hyper-accelerated procedures via an important quantitive marker of 1O2 which is the photo-oxidation of 1,3 diphenylisobenzofuran (DPBF). METHODS: %0.1 riboflavin-containing wells were irradiated with UVA light (365-nm wavelength) with or without 2-4-6-8 L/min oxygen flow assistance. Measurements of decrease in absorbance of DPBF were made in 30 mW (hyper-accelerated), 9 mW (accelerated), and 3 mW UV-A (standard) applications, and with additional 2-4-6-8 L/min oxygen flow in 30 mW and 2 L/min oxygen flow in 9 mW. A total of 8 different UV-A irradiance with and without oxygen supplementation groups were formed. RESULTS: 2 L/min oxygen assisted accelerated UV-A irradiance group has shown a greater decrease in DPBF absorbance compared to Dresden protocol. (p = 0.014) Also, Dresden protocol has shown a greater decrease in DPBF compared to all groups except accelerated crosslinking with 2 L/min oxygen. (p < 0.001) Oxygen assisted hyper-accelerated crosslinking groups were showed greater reduction in DPBF absorbance compared to standard crosslinking without oxygen groups. (p < 0.001). CONCLUSION: Oxygen supplementation may increase the singlet oxygen generation to the similar levels of Dresden Protocol's in accelerated group. Also, more singlet oxygen generation with oxygen supplementation compared to standard UV-A application might be considered to be promising in terms of shortening the crosslinking therapy.


Assuntos
Ceratocone , Fotoquimioterapia , Colágeno/uso terapêutico , Reagentes de Ligações Cruzadas/uso terapêutico , Humanos , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Oxigênio Singlete/uso terapêutico
7.
J Curr Glaucoma Pract ; 15(1): 36-39, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34393455

RESUMO

AIM AND OBJECTIVE: To present a case with bleb leakage treated with collagen crosslinking (CXL). BACKGROUND: Bleb-related complications can cause serious problems even a long time after trabeculectomy. In this case report, we present a relatively unknown treatment method for bleb leakage which might be one of the long-term complications of trabeculectomy. CASE DESCRIPTION: A 60-year-old male patient was admitted to our clinic with a decrease in his left vision. The patient had a history of left trabeculectomy. The bleb leakage was observed. Autologous blood was injected into the bleb area as the first line of treatment. Collagen crosslinking was applied to the bleb area upon the recurrence of the leakage. In the 1st week after the CXL, CXL was repeated in the bleb area upon the observation that the leakage recurred. It was observed that the leakage did not recur and bleb vascularization was triggered after CXL. CONCLUSION: Conjunctival CXL might be a non-invasive, viable method in the management of bleb leakage. It might be applied in conjunction with bandage contact lenses for the treatment of late bleb leaks as an alternative treatment method before going into surgical intervention. CLINICAL SIGNIFICANCE: As a result of conjunctival CXL application, collagen permeability reduction and neovascularization secondary to CXL application might be effective in preventing bleb leakage. However, further studies are needed to prove this. HOW TO CITE THIS ARTICLE: Aktas Z, Aribas YK, Bilgihan K, et al. Collagen Crosslinking-assisted Treatment of a Bleb Leak: Enhancement of Vascularization around the Bleb. J Curr Glaucoma Pract 2021;15(1):36-39.

8.
Cornea ; 39(12): 1533-1540, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32947403

RESUMO

PURPOSE: To evaluate the effects of the application of iontophoresis-assisted rose bengal and green light cross-linking (I-RGX) therapy on enucleated rabbit eyes for corneal biomechanical parameters, dye diffusion rates, and green light levels reaching deep tissues and to compare these parameters with a standard rose bengal and green light cross-linking (RGX) therapy. METHOD: Forty-five enucleated rabbit eyes were used in this study. To evaluate biomechanical changes, corneas were divided into the following 4 groups: the control group, the 0.1% rose bengal application group, the RGX group (100 J/cm), and the I-RGX group (100 J/cm). After this, corneal strips were evaluated with a uniaxial extensometer. To assess corneal dye diffusion, postprocedure dye depth was recorded with anterior segment optic coherence tomography. The amount of irradiation passing through the cornea during irradiation with 250 mW/cm irradiation power was measured with a laser power meter at the first, third, and seventh minutes. RESULTS: In the I-RGX-treated group especially, the mean elastic modulus and corneal stiffness values were about 4.7 times higher when compared with the controls and about 2.2 times higher than those in the RGX group. The rose bengal diffusion depth was 26.63% ± 3.84% of the total corneal thickness in the rose bengal drop group, but this value increased to 42.22% ± 4.77% in the iontophoresis group (<0.001). After iontophoresis, an average of 98% of the 100 J/cm green light was kept in the cornea. CONCLUSIONS: I-RGX is a very useful method for increasing corneal biomechanical strength and is highly effective in increasing the amount of corneal dye diffusion into the cornea while also minimalizing the amount of laser passage reaching deeper tissues.


Assuntos
Córnea/efeitos dos fármacos , Reagentes de Ligações Cruzadas , Corantes Fluorescentes/uso terapêutico , Iontoforese/métodos , Luz , Rosa Bengala/uso terapêutico , Animais , Fenômenos Biomecânicos/fisiologia , Colágeno/metabolismo , Córnea/diagnóstico por imagem , Córnea/metabolismo , Córnea/fisiopatologia , Elasticidade/fisiologia , Enucleação Ocular , Fotoquimioterapia/métodos , Coelhos , Tomografia de Coerência Óptica
9.
Curr Eye Res ; 45(10): 1205-1210, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32065854

RESUMO

Purpose: To evaluate the in vivo efficacy of rose bengal (RB)-mediated photodynamic antimicrobial therapy (PDAT) for treatment of Acanthamoeba castellanii keratitis (AK). Materials and Methods: An animal (rabbit) AK model was successfully achieved via intrastromal inoculation of a suspension of A. castellanii cells and trophozoites. Prior to RB-PDAT (pre-treatment, day-5), the severity of the induced corneal infection was graded numerically for epithelial defects, stromal edema, neovascularity, and stromal opacity/infiltration. The right eyes of rabbits (n = 18) were divided equally into three groups (n = 6/group): control (no treatment); 0.1% RB+518 nm irradiation (5.4 J/cm2); and 0.2% RB+518 nm irradiation (5.4 J/cm2). On post-treatment day-5, animals were euthanized, after which corneal buttons were excised and submitted for real-time polymerase chain reaction (RT-PCR) analysis. Results: Post-treatment clinical scores of the 0.1 and 0.2% RB groups indicated significant improvement compared to control group scores (pre-treatment clinical scores; 5.17 ± 0.98, 7.50 ± 0.62, and 6.17 ± 0.70 and post-treatment clinical scores; 4.50 ± 0.56, (p = .043), 3.50 ± 0.99 (p = .039), 6.83 ± 1.66 (p = .34), respectively). RT-PCR analysis revealed that the mean cycle threshold (Ct) values were significantly higher in treated-group corneas compared to control-group corneas, with no significant differences between treated-groups (Mean Ct values; 34.33, 34.5, and 29.67 for 0.1 and 0.2% RB, and control groups). There was a statistically significant negative correlation between post-treatment clinical scores and Ct values (r = -0.474, p-value 0.047). Conclusions: Our results demonstrate that RB-PDAT is effective in decreasing the parasitic load and clinical severity of AK.


Assuntos
Ceratite por Acanthamoeba/tratamento farmacológico , Antiprotozoários/uso terapêutico , Corantes Fluorescentes/uso terapêutico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Rosa Bengala/uso terapêutico , Ceratite por Acanthamoeba/diagnóstico , Acanthamoeba castellanii/efeitos dos fármacos , Acanthamoeba castellanii/fisiologia , Animais , Córnea/parasitologia , DNA de Protozoário/genética , DNA de Protozoário/isolamento & purificação , Modelos Animais de Doenças , Carga Parasitária , Coelhos , Reação em Cadeia da Polimerase em Tempo Real
10.
Beyoglu Eye J ; 5(1): 53-56, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-35098063

RESUMO

To the best of our knowledge, this is the second reported case of Acanthamoeba keratitis (AK) as a result of scleral lens use and the first case of AK associated with Maxim scleral lens use (Accu-Lens, Inc., Lakewood, CO, USA). A 22-year-old male scleral lens user presented at the department of ophthalmology at Gazi University Hospital complaining of painful corneal opacities and erosion in the cornea of right eye. A real-time polymerase chain reaction assay (Primerdesign, Southampton, UK) was performed, and Acanthamoeba spp. DNA was amplified on the corneal specimen. A topical antimicrobial treatment was prescribed, and the symptoms had improved significantly at the 2-week follow-up. Contact lens wearers always run the risk of developing AK, even with gas-permeable scleral contact lenses. Therefore, AK must be considered as an important differential diagnosis in patients who use scleral contact lenses.

11.
Eye Contact Lens ; 45(6): 360-364, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31170117

RESUMO

PURPOSE: To evaluate long-term corneal morphological changes after photorefractive keratectomy (PRK) using in vivo confocal microscopy (IVCM) and specular microscopy. METHODS: This comparative case-control study included 16 eyes of 8 patients who underwent PRK for mild to moderate myopia 20 years ago and 30 eyes of 15 sex- and age-matched healthy controls. Corneal epithelial cells, sub-basal nerves, keratocytes (anterior, midstromal, and posterior), and endothelial cells were evaluated in both groups 10 and 20 years after surgery. Long-term visual outcomes were also recorded. RESULTS: In vivo confocal microscopy examination revealed similar epithelial morphology, sub-basal nerve fiber morphology/density, mid/posterior stromal keratocyte density, and endothelial cell density between PRK patients and controls at their 10th and 20th year follow-up. Anterior stromal keratocyte density was lower at 10th year; however, it reached to control group value at 20th year follow-up. Extracellular matrix reflectivity was slightly higher, and there was a trace subepithelial corneal haze in PRK group (milder in 20th year than 10th year) compared with controls. At the 20th year, uncorrected distance visual acuity was 20/20 or more in 6 eyes (37.5%), 20/40 or more in 16 eyes (100%), and all eyes had corrected distance visual acuity of 20/20 or better (spherical equivalent -0.31±0.37 D). CONCLUSIONS: Photorefractive keratectomy in low to moderate myopia seems to be safe and effective method in the long term with preserving corneal morphology (including anterior stromal keratocyte and sub-basal nerve fiber density) and refractive outcomes as shown in this study. In appropriate patients, this method can be considered confidently.


Assuntos
Córnea/inervação , Ceratócitos da Córnea/citologia , Epitélio Corneano/citologia , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Ceratectomia Fotorrefrativa , Nervo Trigêmeo/citologia , Estudos de Casos e Controles , Contagem de Células , Endotélio Corneano/citologia , Feminino , Seguimentos , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Miopia/fisiopatologia , Microscopia com Lâmpada de Fenda , Acuidade Visual/fisiologia , Cicatrização/fisiologia
12.
Beyoglu Eye J ; 4(3): 206-209, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-35187460

RESUMO

To present a case with progressive keratoconus after treated with radial keratotomy (RK) and was undergone corneal collagen cross-linking (CXL) for preventing the progress of keratectasia. A progressive keratoconus case who was previously treated with RK was undergone corneal collagen cross-linking (CXL) in her left eye for preventing the progress of keratectasia. After the CXL procedure performed at another clinic, best-corrected visual acuity (BCVA) of her left eye decreased from 0.9 to 0.6 Snellen lines in an 8-months follow-up. Pre CXL maximum keratometric power (P-Kmax) was also increased from 52.1 to 57.16 Diopter (D) in the eight months after CXL. Applying CXL on the keratoconic patient previously treated with RK should be questioned.

13.
Acta Ophthalmol ; 97(1): e91-e96, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29862655

RESUMO

PURPOSE: To compare the antifungal efficacy of corneal collagen cross-linking with photoactivated riboflavin (PACK-CXL) and voriconazole in experimental Fusarium solani and Candida albicans keratitis models. METHODS: Sixty-four corneas of 32 New Zealand rabbits were included and divided into two main groups. Intrastromal injection of Fusarium and Candida suspensions was performed, and it was observed that keratitis was formed on the third day. Both groups were randomly separated into the following four groups: control, PACK-CXL, voriconazole and PACK-CXL combined with voriconazole. PACK-CXL was applied using 0.25% riboflavin in an accelerated Dresden protocol (total ultraviolet A dose 5.4 J/cm²). Voriconazole was applied topically as 7x1/day with a dose of 1% (10 mg/ml). Corneal buttons were excised on the tenth day, and microbiological and pathological examinations were performed. RESULTS: The PACK-CXL and PACK-CXL combined with voriconazole groups each had 100 colony-forming unit (CFU/ml) of reproduced micro-organisms compared with 500 CFU/ml in the voriconazole group and 1500 CFU/ml in the control group (p < 0.001) in the Fusarium keratitis model. The PACK-CXL combined with voriconazole group had 100 CFU/ml, the PACK-CXL group had 150 CFU/ml, and the voriconazole group had 200 CFU/ml of reproduced micro-organisms compared with 4000 CFU/ml in the control group (p < 0.002) in the Candida keratitis model. (p < 0.001). Fewer hyphae and non-specific stromal changes were observed in the pathological cross sections examined in subgroups that used CXL. CONCLUSION: There was less fungus reproduction and a lower keratitis score for Fusarium solani and Candida albicans in the treatment groups compared to the control groups, especially in groups that used PACK-CXL. These results suggest that it is useful to combine PACK-CXL treatment with medical treatment in the fungal keratitis algorithm at the early stage of the disease.


Assuntos
Colágeno/uso terapêutico , Córnea/patologia , Reagentes de Ligações Cruzadas/uso terapêutico , Infecções Oculares Fúngicas/tratamento farmacológico , Ceratite/tratamento farmacológico , Fotoquimioterapia/métodos , Voriconazol/uso terapêutico , Animais , Antifúngicos/uso terapêutico , Candida albicans/isolamento & purificação , Córnea/microbiologia , Modelos Animais de Doenças , Infecções Oculares Fúngicas/microbiologia , Infecções Oculares Fúngicas/patologia , Ceratite/microbiologia , Ceratite/patologia , Fármacos Fotossensibilizantes/uso terapêutico , Coelhos , Riboflavina/uso terapêutico , Raios Ultravioleta
14.
Cornea ; 37(11): 1463-1467, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30161054

RESUMO

PURPOSE: To investigate voriconazole (VRZ) penetration and fungal load in the cornea after applying VRZ therapy with various treatment combinations in a fungal keratitis model. METHODS: Fifty-four eyes of 27 young albino rabbits were provided for this experimental study. Twelve corneas were inoculated with Candida albicans, 12 corneas were inoculated with Fusarium solani, and 6 eyes were selected as controls. Infected corneas received various treatment combinations including VRZ 1% drop therapy alone, VRZ 1% plus amphotericin B 1% drop combination therapy, iontophoretic VRZ therapy, and VRZ 1% drop therapy after corneal cross-linking. Fungal load was measured by log reduction, and VRZ levels were quantified by liquid chromatography-tandem mass spectrometry. RESULTS: Iontophoresis-assisted VRZ application showed the highest antifungal activity against F. solani keratitis (4-log reduction) and C. albicans keratitis (5-log reduction) compared with other treatment applications. VRZ levels were also found to be the highest in corneas that received iontophoretic VRZ treatment (3.6313 ± 0.0990 ppb for F.solani keratitis and 1.7001 ± 0.0065 ppb for C. albicans keratitis) compared with other treatment applications. CONCLUSIONS: Iontophoresis seems to provide the highest VRZ concentration and highest antifungal activity in the cornea compared with other treatment applications for C. albicans and F. solani keratitis.


Assuntos
Antifúngicos/uso terapêutico , Córnea/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Infecções Oculares Fúngicas/tratamento farmacológico , Iontoforese , Fotoquimioterapia/métodos , Voriconazol/uso terapêutico , Animais , Antifúngicos/farmacocinética , Candida albicans/isolamento & purificação , Candidíase/tratamento farmacológico , Colágeno/metabolismo , Córnea/microbiologia , Modelos Animais de Doenças , Fusariose/tratamento farmacológico , Fusarium/isolamento & purificação , Ceratite/tratamento farmacológico , Coelhos , Raios Ultravioleta , Voriconazol/farmacocinética
15.
Curr Eye Res ; 43(11): 1322-1325, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30021467

RESUMO

PURPOSE: To evaluate the antiamoebic properties of photo-activated chromophore for keratitis (PACK)-corneal cross-linking (CXL) (PACK-CXL), in combination with riboflavin (0.1 and 0.25%) or rose bengal (0.1 and 0.2%), for treatment of Acanthamoeba trophozoites and cysts. MATERIALS AND METHODS: Cultures of Acanthamoeba castellanii were grown in a fluid medium at a concentration of 2.7 × 105 cell/ml. PACK-CXL was used on A. castellani cells in combination with either riboflavin (0.1 and 0.25%) or rose bengal (0.1 and 0.2%). Riboflavin-containing wells were irradiated with ultraviolet-A (UVA) light (365-nm wavelength). Rose bengal-containing wells were irradiated with green light (523-nm wavelength). A power density of 9 mW/cm2 for 10 min and total irradiation dose of 5.4 J/cm2 was used for both riboflavin and rose bengal. After UVA and green light irradiation, cell viabilities were evaluated, and percentage of dead cells calculated. RESULTS: No significant amoebicidal activity was observed following PACK-CXL/riboflavin at either concentration. PACK-CXL/rose bengal, however, was observed to be highly effective in eradicating Acanthamoeba cells at either concentration, with no significant difference observed between the two concentrations. The percentage of dead cells was 63% following treatment at either rose bengal concentration. CONCLUSION: PACK-CXL with rose bengal demonstrated pronounced antiamoebic activity against A.castellanii. Further in vitro and in vivo studies are needed to confirm this finding.


Assuntos
Ceratite por Acanthamoeba/tratamento farmacológico , Acanthamoeba/efeitos dos fármacos , Infecções Oculares Parasitárias/tratamento farmacológico , Riboflavina/farmacologia , Rosa Bengala/farmacologia , Trofozoítos/efeitos dos fármacos , Acanthamoeba/isolamento & purificação , Ceratite por Acanthamoeba/microbiologia , Ceratite por Acanthamoeba/patologia , Infecções Oculares Parasitárias/microbiologia , Infecções Oculares Parasitárias/patologia , Corantes Fluorescentes/farmacologia , Humanos , Fármacos Fotossensibilizantes/farmacologia , Trofozoítos/isolamento & purificação
16.
Eye Contact Lens ; 44(3): e10-e12, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-27203793

RESUMO

We presented a case of refractory dry eye management with semi-scleral contact lens. Dry eye was associated with facial nerve (cranial nerve VII) palsy as a result of cerebellopontine angle tumor surgery. She was treated with several topical treatments and punctal plug. Despite the treatments, her symptoms still persisted. Her ophthalmic examination revealed scleral exposure because of lagophthalmos, conjunctival hyperemia, corneal debris, scar, and diffuse punctate epitheliopathy on her right eye. Lissamine green staining showed diffuse conjunctival and corneal staining. Therapeutic semi-scleral lenses were fitted. The corneal findings were resolved and the quality of patient life was improved with the aid of semi-scleral lens after 3 months.


Assuntos
Lentes de Contato , Síndromes do Olho Seco/terapia , Feminino , Humanos , Pessoa de Meia-Idade , Qualidade de Vida , Esclera
17.
Mycopathologia ; 183(2): 329-336, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29043533

RESUMO

The aim of our study was to investigate matrix metalloproteinases, MMP-9 and MMP-13 levels, in the rabbit model of Fusarium and Candida keratitis treated by corneal cross-linking (PACK-CXL). Rabbit corneas were inoculated with fungal inoculum for keratitis. Each group divided into four subgroups, including un-treated group, PACK-CXL group, voriconazole group and PACK-CXL plus voriconazole group. PACK-CXL was applied with 0.25% riboflavin in accelerated Dresden protocol, and 0.1% voriconazole drops were administered. All corneal buttons excised at tenth day after ophthalmological examination. Fungal cell counts and Scheiber scores were determined in all groups. Corneal tissue MMP mRNA levels were evaluated quantitative reverse transcriptase PCR. The difference in MMP-9 and MMP-13 levels at all groups was not statistically significant (p > 0.05). PACK-CXL with 0.25% riboflavin either alone or combined with antifungal drops was unable to provide decline in inflammatory findings in both macroscopic and microscopic levels similar to medical antifungal treatment.


Assuntos
Candida/crescimento & desenvolvimento , Reagentes de Ligações Cruzadas/administração & dosagem , Fusarium/crescimento & desenvolvimento , Ceratite/tratamento farmacológico , Ceratite/patologia , Metaloproteinase 13 da Matriz/análise , Metaloproteinase 9 da Matriz/análise , Animais , Córnea/patologia , Modelos Animais de Doenças , Perfilação da Expressão Gênica , Ceratite/microbiologia , Metaloproteinase 13 da Matriz/genética , Metaloproteinase 9 da Matriz/genética , RNA Mensageiro/análise , Coelhos , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Resultado do Tratamento
18.
Cornea ; 36(12): 1492-1497, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28922329

RESUMO

PURPOSE: To compare clinical outcomes of conventional corneal cross-linking (C-CXL) and diluted alcohol and iontophoresis-assisted corneal cross-linking (DAI-CXL) for the treatment of progressive keratoconus (KC). METHODS: Ninety-three eyes of 80 patients with KC were treated by C-CXL (n = 47) or DAI-CXL (n = 46). Visual acuity, keratometry, KC indexes, pachymetry, and aberrations were recorded before treatment and 1, 3, 6, and 12 months after treatment. The demarcation line was assessed 1 month after treatment. RESULTS: A significant improvement in visual acuity was observed at month 3 and month 6 after DAI-CXL and C-CXL, respectively. A significant decrease in maximum keratometry was observed in both groups at month 6. The front symmetry index significantly improved in both groups after 6 months, whereas the Baiocchi Calossi Versaci index significantly improved only after DAI-CXL at month 12 (P = 0.01). Average keratometry and other KC indexes were stable during 12 months of follow-up. Central corneal thickness decreased by 28.6 and 40.2 µm after DAI-CXL and C-CXL at month 1, respectively (P < 0.01), and it reached baseline at the 12th month (P = 0.14) only in the DAI-CXL group. Higher-order aberrations, coma, and spherical aberration significantly worsened at month 1 (P < 0.01) only after C-CXL; however, they improved significantly at month 12 compared with baseline (P < 0.05) in both groups. The demarcation line was visible in all cases at month 1 at a mean depth of 302 ± 56 µm and 311 ± 57 µm after DAI-CXL and C-CXL, respectively (P = 0.7). CONCLUSIONS: The DAI-CXL protocol seems as effective as the C-CXL protocol in halting KC progression after 1 year of follow-up.


Assuntos
Colágeno/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Iontoforese/métodos , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Adulto , Córnea/metabolismo , Córnea/patologia , Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea , Etanol/administração & dosagem , Feminino , Humanos , Masculino , Estudos Prospectivos , Acuidade Visual , Adulto Jovem
19.
Clin Exp Optom ; 100(4): 369-374, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27654998

RESUMO

BACKGROUND: The aim was to investigate changes in corneal sensation and rigid gas-permeable (RGP) contact lens tolerance after corneal cross-linking (CXL) on patients with keratoconus. METHODS: Thirty eyes of 30 patients, who were RGP lens intolerant, were treated with CXL. The main outcome measures were corneal sensation evaluation by Cochet-Bonnet esthesiometry, sub-basal nerve fibre assessment by corneal in vivo confocal microscopy and RGP contact lens tolerance evaluation with the Likert scale and wearing time. All eyes were evaluated preoperatively and post-operatively at one, three and six months after CXL procedure. RESULTS: The mean age was 25.3 ± 6.2 years. Preoperatively, the maximum keratometry (Kmax) in study eyes was 56.89 ± 4.60 D. Six months after CXL, it reduced to 56.03 ± 4.85 D (p = 0.01). Preoperative mean corneal sensation was 0.44 ± 0.05 g/mm2 , (range: 0.40 to 0.55); it was significantly decreased at the first month and increased to preoperative values after six months. The sub-basal nerve plexus could not be visualised in 90 per cent of the patients by confocal microscopy at one month post-operatively. Gradual restoration of corneal innervation with almost similar preoperative levels at post-operative month six was noted. There were significant differences in Likert scores between preoperative and third and sixth months after CXL. Likert scale scores correlated significantly with corneal sensitivity. CONCLUSION: It can be concluded that increased RGP contact lens tolerance after CXL may be associated with the potential role of decreased corneal sensitivity and corneal flattening after CXL.


Assuntos
Colágeno/farmacologia , Lentes de Contato , Córnea/inervação , Reagentes de Ligações Cruzadas/farmacologia , Ceratocone/tratamento farmacológico , Nervo Oftálmico/fisiopatologia , Fotoquimioterapia/métodos , Adolescente , Adulto , Criança , Córnea/patologia , Topografia da Córnea , Feminino , Seguimentos , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Masculino , Microscopia Confocal , Regeneração Nervosa/efeitos dos fármacos , Sensação/fisiologia , Resultado do Tratamento , Raios Ultravioleta , Adulto Jovem
20.
Curr Eye Res ; 41(12): 1539-1542, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27216990

RESUMO

PURPOSE: Nitric oxide production can cause either apoptotic or necrotic cell death through oxidative stress. We aimed to investigate the nitrite oxide metabolites (NOx) and nitrite levels in the aqueous humor of rabbit eyes after different methods of corneal collagen cross-linking (CXL). MATERIALS AND METHODS: Twenty-four eyes of 12 adult New Zealand rabbits were used. They were assigned into four groups, each including six eyes. Group 1 (control) consisted of eyes with no treatment. Group 2 received UV-A power setting at 3 mW/cm2 for 30 minutes of continuous exposure and named as standard CXL group. Group 3 received UV-A power setting at 30 mW/cm2 for 3 minutes of continuous exposure and named as accelerated CXL (A-CXL) group. Group 4 received UV-A power setting at 30 mW/cm2 for 6 minutes of pulsed exposure (1 sec on, 1 sec off) and named as pulse-light accelerated CXL (PLA-CXL). Aqueous humors were aspirated from anterior chamber with a 27G needle after 1 hour UV-A exposure. NOx and nitrite levels were measured Results: The nitrite levels in aqueous humor were significantly increased in Group 2 and Group 3 when compared with Group 1 (p = 0.000, p = 0.036, respectively). When treatment modalities were compared with each other, high nitrite level in Group 2 was statistically significant when compared with Group 4 (p = 0.019). NOx levels were higher in Group 2 when compared with Group 1 (p = 0.006). CONCLUSIONS: Numerous studies investigated the physiological and pathophysiological roles of NO. NO is considered one of the most important molecule for ocular health. According to NOx level in aqueous humor, it seems that PLA-CXL is the safest method due to the similar results with control group.


Assuntos
Humor Aquoso/metabolismo , Colágeno/farmacologia , Córnea/metabolismo , Reagentes de Ligações Cruzadas/farmacologia , Ceratocone/tratamento farmacológico , Óxido Nítrico/metabolismo , Estresse Oxidativo , Riboflavina/farmacologia , Acuidade Visual , Animais , Modelos Animais de Doenças , Ceratocone/metabolismo , Fármacos Fotossensibilizantes/farmacologia , Coelhos , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...